XD1+ SOFTWARE TUTORIAL

DEVICE MAINTENANCE SETTINGS

To keep your XD1+ device running optimally, we recommend running a Compliance Check on the device every 90 days. To perform a compliance check on a device we recommend that you purchase a Trolex Compliance Pack+. 

In addition to running a compliance check, we recommend that you always keep your device’s firmware up to date to ensure optimal performance and security. We recommend that you enable the ‘Check for Firmware Updates’ in the app settings. 

BreatheLITE Device Maintenance tutorial: Settings walkthrough

COMPLIANCE CHECK

To run a compliance check on a device ensure you’ve connected your XD1+ device to the software. Click the Device button and select Compliance check and the following screen will then by displayed:  

  1. To run the Compliance Check, make sure you have the Trolex Compliance Pack ready and then click on the start button. The Compliance Check process will then begin.  
  2. The display will inform the user to dose the device with the permitted dust spray available from Trolex. Spray the device for the duration of the test. 
  3. Once the test has finished, the result will then be displayed stating whether the device has passed or failed. 
  4. Click the Close button once the test has finished to return to the app. 
BreatheLITE Device Maintenance tutorial: Completing a compliance check walkthrough

VIEW PREVIOUS RESULTS

To view previous Compliance Check results, click the Device Button and select Compliance Check. The following screen with then be displayed: 

  1. Click on the Previous Results tab.  
  2. A list of previous results is displayed with timestamps and a clear pass/fail status for each device. 
BreatheLITE Device Maintenance tutorial: Viewing previous results

AUTOMATICALLY UPDATING FIRMWARE

Upgrading your device’s firmware is an important step to keep it running smoothly and securely. However, it’s important to note that this process will erase all of the data on your device. Before proceeding with the update, we highly recommend downloading all of the data before updating.  

  1. Locate the Settings and make sure the Automatically Check for Firmware Updates box is checked. 
  2. In the Devices section, you will see the devices that have a firmware update. 
  3. Click on the Devices button and select Firmware Update.  
  4. A new popup will then be displayed, click on the Update button to progress. 
  5. The firmware will then be downloaded onto the device. 
  6. Once the firmware has been downloaded onto the device, the firmware will then be verified. 
  7. Once the firmware has been verified, it will the display whether it was updated successfully or not. 
  8. Once finished, click on the close button. 
BreatheLITE Device Maintentance tutorial: Automatically updating firmware

MANUALLY UPDATING FIRMWARE

Upgrading your device’s firmware is an important step to keep it running smoothly and securely. However, it’s important to note that this process will erase all of the data on your device. Before proceeding with the update, we highly recommend downloading all of the data before updating. 

To update the device firmware, please follow the steps below: 

  1. Within the app Settings, make sure the Automatically Check for Firmware Updates is disabled. 
  2. Click the Device Button and select Firmware Update. 
  3. The firmware update dialog box with be displayed. 
  4. Select the TDFU file to upload to the device by clicking on the Browse section and a select file dialog will be displayed. Choose the TDFU file to upload. 
  5. Select update, and the firmware will be downloaded onto the device. 
  6. Once the firmware has been downloaded onto the device, the firmware will then be verified. 
  7. Once the firmware has been verified, it will then display whether it was updated successfully or not. 
  8. Once finished, click on the close button. 

GOT PRODUCT QUESTIONS?

If the Trolex XD1+ STEL and TWA indicators are flashing red as shown below:

This means the Trolex XD1+ has detected an electronic failure of the internal memory. The XD1+ will alert the user and enter an error state.

If this happens, please contact our support team to raise a ticket.

AIR XD operates a protective thermal cut-out sequence when the temperature inside the instrument exceeds the maximum operating temperature of 45 °C.

This protective measure is in place to maintain the lifespan and operating functionality of the optical sensor assembly when the AIR XD is installed in environments with high ambient temperatures.

If the internal temperature of the instrument is suspected to be below -10°C, for example, if it has been left powered off for a period of time in a very cold environment, damage to the optical assembly may occur when power is applied.

Allow the instrument to reach safe operating temperature before applying power.

If all three device indicators are flashing red as shown below, this means the device has a non-recoverable operating error. 

If this is happening to your Trolex XD1+ device, please contact the Trolex service team to raise a new support ticket

Our AIR X Particulate Monitors don’t hold any of these accreditations.

No. The Group I manual states that the USB connector on the base of the equipment shall only be connected to the Trolex TX8805 AIR XD USB Drive in the hazardous area.

USB drives with no power source, such as standard USB sticks, may be connected to the USB connector in the safe area for test purposes.

AIR XD is designed to allow infrequent pressure washing during maintenance schedules, but the inlet cap must be closed first.

Keep an appropriate distance between the pressure washer and the instrument, and do not direct the water jet at the underside of the instrument because water must not enter the air flow path.

Yes. The AIR XD provides in and out RS485 terminals so multiple MODBUS devices can be daisy-chained.

Some network installations may require a termination resistor across RS485 lines A and B.

MORE RESOURCES

PARTICULATE MONITORING

Image of TX8061 XD1+ Personal Dust Monitor
TX8061 XD1+ Personal Dust Monitor

Image of AIR X Software
AIR X Software

Image of TX8005 AIR XD Dust Monitor
TX8005 AIR XD Dust Monitor

Image of TX8100 AIR XS Silica Monitor
TX8100 AIR XS Silica Monitor

AIR X NEWS + CASE STUDIES

GET AIR X NEWS + UPDATES

    You may unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and how we are committed to protecting and respecting your privacy, please review our Privacy Policy.