INDUSTRY RISKS
· OIL + GAS PRODUCTION

The National Institute of Health reports oil + gas industry occupational fatality rate is 2.5 x higher than the construction industry. A factor causing this is exposure to hazardous chemicals, fumes and particulates, such as Diesel Particulate Matter (DPM).

What are the risks?

  • Diesel Particulate Matter
  • Respirable Crystalline Silica (RCS)
  • Carbon Dioxide
  • Hydrogen Sulphide
  • Methane
  • Diesel + other gas leaks

Why may these risks occur?

  • Use of diesel engines + vehicles
  • Use of machinery
  • Use of silica in fracturing
  • Sanding wood
  • Extraction processes
  • Hydraulic fracturing
  • Leaks + spills
  • Use of machinery

PRODUCT SOLUTIONS

Image of Particulate Monitoring
Particulate Monitoring

Image of Gas Detection
Gas Detection

Image of Software Solutions
Software Solutions

Image of Other Products
Other Products

Was this page helpful?

    More detail requiredMore variety of content neededIncorrect informationBroken linksHard to readUnclear page formatting

      DetailVariety of contentUseful informationEasy to readPage formatting

      GET PRODUCT UPDATES

        You may unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and how we are committed to protecting and respecting your privacy, please review our Privacy Policy.

        3 reasons to use SENTRO X in oil refineries

        Working with high volumes of oil in refineries inevitably can lead to gas exposure in the workplace. Most oil refineries use a systematic process which involves several key parts which converts oil into various usable product. 

        Throughout the process, the oil is firstly distilled and separated based on its boiling point, then is converted depending on the size of the molecule through either cracking or reforming and finally is treated through either hydrotreatment or hydrocracking. These processes work to transform oil into multiple usable products. 

        In this process, as oil is converted into various products, with varying boiling points, range, density, etc. meaning that exposure to hazardous gas is likely for the workers throughout the different stages of the process. Effective gas detection can help to protect workers from exposure to dangerous levels

        Exposure to hazardous gases can happen at any time, during any stage of the oil refinery process. Consistent monitoring of each process, alongside sources such as boilers, furnaces and cracking units are essential to ensure workers are protected. SENTRO X is lightweight and easily installable nature which means it can be fitted nearby each process at ease, with a simple power-up routine, so you’re always detecting gas. 

        Highly flammable gases such as Hydrogen and Methane are commonly formed as a byproduct of the refinery process. These gases not only present a health risk to exposed workers but also demonstrates a wider physical risk across the entire workplace. With optional A/V alarms, ingress protected to IP65, alongside an audio warnings, SENTRO X provides reliable alerts of exposure to flammable gases. 

        Oil refineries aren’t just at risk of explosions. Highly toxic gases such as Hydrogen Sulphide and Ammonia are formed throughout various stages in oil refinery processes. With exposure to multiple gases common in oil refineries, throughout various stages, compatible gas sensing blocs (gBlocs) ensures SENTRO X can easily monitor for up to 20 variants of gases, without hassle throughout the entire process. 

        GAS DETECTION

        Image of TX6310 SENTRO X Gas Detector
        TX6310 SENTRO X Gas Detector

        Image of TX9165 SENTRO 8
        TX9165 SENTRO 8

        Image of TX6351-2 SENTRO 1
        TX6351-2 SENTRO 1

        Image of TX6355 SENTRO Wireless
        TX6355 SENTRO Wireless

        GET PRODUCT UPDATES

          You may unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and how we are committed to protecting and respecting your privacy, please review our Privacy Policy.

          3 reasons to use SENTRO X in forecourt and fuel management

          Whilst many of us take little notice of the surrounding environment when filling our cars up with petrol or diesel, there’s actually a lot more than meets the eye. Forecourt and fuel management ensures that the set-up, maintenance and running of petrol stations are as expected. 

          However, this encompasses its own issues. Maintenance on both the forecourt, and also in underground storage tanks for both petrol and diesel is regularly required, meaning individuals can be exposed to dangerous gases, often at hazardous levels. 

          This regular exposure to both diesel and petrol, at high volumes and often in enclosed or restricted areas, whether on the forecourt or in underground storage tanks, can lead to overexposure and subsequent health concerns, including lung cancers, respiratory and allergic irritations. Effective gas detection is often needed. 

          In forecourt and fuel management, there are multiple locations where excess gas may need to be detected. Whether its determining leaks which the public may be exposed to, or in underground areas where airflow and ventilation is limited and gas can build up, easy installed gas detection is essential to ensure all workers are well protected. 

          Due to the flammable nature of petrol and diesel, effectively detecting for gas leaks or overexposure to hazardous gases is essential when maintaining fuel tanks and forecourts. SENTRO X is compatible for gas sensing blocs (gBlocs) for a range of flammable gases, meaning that when maintaining petrol tanks and surrounding areas, it’s the essential tool for protecting workers from the risk of fires or explosions. 

          In an environment where hazardous liquids and gases commonly occur and where workers are often at risk, you need a detector which can withstand anything. SENTRO X is built and designed with EMC protected and proof against surface electrostatic discharge, as well as reinforced PC/ABS polymer, to operate in all environments no matter the risk. 

          GAS DETECTION

          Image of TX6310 SENTRO X Gas Detector
          TX6310 SENTRO X Gas Detector

          Image of TX9165 SENTRO 8
          TX9165 SENTRO 8

          Image of TX6351-2 SENTRO 1
          TX6351-2 SENTRO 1

          Image of TX6355 SENTRO Wireless
          TX6355 SENTRO Wireless

          PRODUCT SALES ENQUIRIES

          GET PRODUCT UPDATES

            You may unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and how we are committed to protecting and respecting your privacy, please review our Privacy Policy.

            5 health risks linked to occupational dust exposure

            1. Occupational lung diseases

            Arguably the most well-known and common risk associated with exposure to hazardous dusts in the workplace relate to occupational lung diseases. Diseases such as Silicosis, Chronic Obstructive Pulmonary Disease (COPD), Black Lung Disease and occupational lung cancer all are associated with dust inhalation in the workplace. 

            2. Respiratory illness and irritation

            Whilst long-term exposure to breathing in dust can lead to lung diseases, initial, short-term exposure to hazardous dusts can lead to respiratory illness and irritation. Breathing in dust such as Respirable Crystalline Silica (RCS) and wood dust can cause serious respiratory diseases; the NHS claim it’s the third biggest cause of death in England. 

            3. Cardiovascular diseases

            Exposure to breathing in hazardous dust can lead to cardiovascular diseases and other heart and blood vessel issues. Dust and hazardous particulates can easily travel through your bloodstream and deep into your lungs, damaging your blood vessels in the process. This can increase blood pressure and make it more likely to give you blood clots. 

            4. Occupational asthma

            The British Thoracic Society reports that occupational asthma is responsible for roughly 1/6 cases of adult-onset asthma. Occupational asthma can be caused by various types of dust in multiple different industries, such as flour dust, wood dust, grain dust and various fumes from metals.  

            5. Long-term health concerns

            There have been examples of various other health concerns relating to workplace exposure to hazardous dust. Skin, eye and nose irritation, as well as some rare examples of kidney disease have all been linked to examples where workers have failed to protect themselves against hazardous dust. 

            PARTICULATE MONITORING

            Image of TX8100 AIR XS Silica Monitor
            TX8100 AIR XS Silica Monitor

            Image of TX8061 XD1+ Personal Dust Monitor
            TX8061 XD1+ Personal Dust Monitor

            Image of TX8005 AIR XD Dust Monitor
            TX8005 AIR XD Dust Monitor

            Image of TX8060 XD ONE Portable Dust Monitor
            TX8060 XD ONE Portable Dust Monitor

            GET AIR X UPDATES