XD1+ SOFTWARE TUTORIAL

MANAGING DEVICES

BreatheLITE centralises management of all your XD1+ devices, simplifying device set-up, alarm configuration and profile management for site monitoring and reporting. Here’s how you can add and configure your XD1+ devices. 

BreatheLITE Devce Management tutorial: Managing devices

ADDING A DEVICE

The simplest way to add a device is to enable Automatic Device Discovery in the App Settings. When this is enabled, devices will automatically be populated after five seconds. If not follow these steps: 

  1. If Automatic Device Discovery is disabled, you can manually add the device by clicking the Add Device button in the Devices section. 
  2. After clicking the Add Device button, a pop-up will be displayed asking you to enter the device’s serial number and model. 
  3. Enter the device’s serial number into the text box and select the device model from the drop down. The device serial number can be found on the back of your XD1+ device.  
  4. After entering the information, click the ave button. Once the device has been added, it will be displayed in the Devices section. 
BreatheLITE Device Management tutorial: Adding a device

DEVICE LIST

Once a device is added to the app, it appears in the Devices section. The device will be shown in colour if its connected, or in greyscale if it’s disconnected. 

For each device, the name is always displayed in the top left-hand corner. Here’s what each icon next to the device icon means:  

  • Device Menu Options:Top right – Open device settings, manage videos and other actions. 
  • Connection Status: Bottom left – Indicates whether a device is connected or disconnected. 
  • Battery: Bottom Middle left – Shows current battery state. Hover to view the exact battery percentage. 
  • Compliance check: Bottom Middle right – Indicates if a compliance check is due. Hover to see the due date. 
  • Firmware: Bottom right – Shows whether firmware is up to date. Hover to view the device’s firmware version. 
BreatheLITE Device Management tutorial: Device list

MENU OPTIONS

To open the device menu, click the Devices Button in the top right and a list of actions will be displayed including:  

  • Settings: Configure XD1+ device preferences and options.
  • Videos: Import and manage videos for this XD1+ device. 
  • Download Data: Download the latest XD1+ device data. 
  • Firmware Update: Update your XD1+ device firmware. 
  • Compliance Check: Run a compliance check on your XD1+ device and view past results. 
  • Identify: Locate or identify a specific XD1+ device. 
  • Clear Data: Remove stored data from your XD1+ device. 
  • Archive: Archive your XD1+ device. 
BreatheLITE Device Management tutoral: Device menu options

CONFIGURE A DEVICE

To configure an XD1+ device for personalisation, click the Devices Button and select Settings. The following options will be available: 

  • Name: Select a name for your XD1+ device. We recommend choosing a name unique to the job or activity you’re working on or the personnel using it. 
  • Operating mode: Select device operating mode based on application. Choose from Normal, Cab, DataLog or Error. 
  • Alarm PM size: Select the Particulate measurement size that the device will alarm on. Choose from PM1, PM2.5, PM4.25 or PM10. 
  • Units: Decide your preferred units of measurement, for either µg/m³ or mg/m³.
  • TWA period (minutes): Set the TWA period to align with working requirements, up to 12 hours. 
  • TWA threshold (µg/m³): Set the TWA Alarm Threshold based on permissible exposure limits. This is the value that the TWA alarm will trigger on once the exposure threshold is reached. 
  • STEL period (minutes): Set the STEL period to align with working requirements, up to 15 minutes. 
  • STEL threshold (µg/m³): Set the STEL Alarm Threshold based on permissible exposure limits. This is the value that the STEL alarm will trigger on once the exposure threshold is reached. 
  • Log rate (Seconds): Set the data log rate for the device. Max log period 60 seconds, minimum 10 seconds. 
  • Minimum shift time (seconds): Set the minimum shift time for the XD1+ in seconds. 
  • Material profile: Choose the dust profile that matches your environment. See more below. 

Once all changes have been made, click the Save button and apply the new settings. A notification will then be displayed to show the device settings were successfully saved. 

 

BreatheLITE Device Management tutorial: Configuring a device

MATERIAL PROFILES

Your XD1+ device supports material profiles that allows you to configure the device based on the type of material being monitored. To configure a material profile, click on the Devices Button and select Settings. In the settings dialogue navigate to the Material Profiles section. 

Click on the Material Profile drop down box and select the material profile you wish to use. The following material profiles are supported: 

  • Default 
  • Flour dust 
  • Metal fabrication 
  • Stone 
  • Wood 

Always ensure that the selected material profile accurately reflects the type of material you are monitoring. If you’re working with one of the listed material profile options, select it from the drop-down list, if you’re working with mixed substances or don’t know what dust you may be exposed to, then select the Default option.  

Once you have selected the material profile, remember to press save. 

BreatheLITE Device Management tutorial: Material profiles

MANUALLY CONNECTING TO A DEVICE

If you have Automatic Device Detection enabled, you can skip this step but if not, follow these steps to manually connect to a device: 

  1. Click on the Devices Button for the relevant XD1+ device and select Connect.  
  2. The app will then attempt to connect to the device. Once connected, the Connection icon will turn green. 
  3. Once the device is connected, you can then change the device settings or download data as shown in the next section. 

DOWNLOADING DATA

If you have Automatic Data Download enabled, the app will automatically download data in the background about a minute after connecting the device. A notification will appear in the Notification Centre when the download is complete. 

If you don’t have this feature enabled, you can manually download the data by following these steps: 

  1. Click on the Devices Button for the relevant XD1+ device and select Download Data. 
  2. The software will then attempt to connect to the device and download the data. 
  3. The dialog box will display the progress of the data download. 
  4. Once all the data is downloaded click the Close button to finish. To view downloaded data, navigate to the Data Analysis section. 
BreatheLITE Device Management tutorial: Downloading data

IDENTIFY A DEVICE

If you have multiple devices connected to the software and you want to know which one is which, you can use the identify feature: 

  1. Click on the Devices Button for the relevant XD1+ device and select Identify. 
  2. The LEDs on the front of the selected device will then flash to identify itself. 
BreatheLITE Device Management tutorial: Identifying a device

CLEAR DATA

If you want to manually clear data from a device: 

  1. Click on the Devices Button for the relevant XD1+ device and select Clear Data. 
  2. A confirmation dialog will appear. 
  3. Click Yes to confirm the deletion of the device or No to cancel. 
  4. Once the data has been cleared, a notification will be displayed to confirm the data was successfully deleted. 
BreatheLITE Device Management tutorial: Manually clear data

ARCHIVE A DEVICE

If you have a device you no longer use, you can archive it to remove it from the active device list without deleting its data, by following these steps:  

  1. Click on the Devices utton for the relevant XD1+ device and select Archive. 
  2. A confirmation dialog will appear.  
  3. Click Yes to confirm the archiving of the device or No to cancel. 
BreatheLITE Device Management tutorial: Archive a device

GOT PRODUCT QUESTIONS?

If the Trolex XD1+ STEL and TWA indicators are flashing red as shown below:

This means the Trolex XD1+ has detected an electronic failure of the internal memory. The XD1+ will alert the user and enter an error state.

If this happens, please contact our support team to raise a ticket.

AIR XD operates a protective thermal cut-out sequence when the temperature inside the instrument exceeds the maximum operating temperature of 45 °C.

This protective measure is in place to maintain the lifespan and operating functionality of the optical sensor assembly when the AIR XD is installed in environments with high ambient temperatures.

If the internal temperature of the instrument is suspected to be below -10°C, for example, if it has been left powered off for a period of time in a very cold environment, damage to the optical assembly may occur when power is applied.

Allow the instrument to reach safe operating temperature before applying power.

If all three device indicators are flashing red as shown below, this means the device has a non-recoverable operating error. 

If this is happening to your Trolex XD1+ device, please contact the Trolex service team to raise a new support ticket

Our AIR X Particulate Monitors don’t hold any of these accreditations.

No. The Group I manual states that the USB connector on the base of the equipment shall only be connected to the Trolex TX8805 AIR XD USB Drive in the hazardous area.

USB drives with no power source, such as standard USB sticks, may be connected to the USB connector in the safe area for test purposes.

AIR XD is designed to allow infrequent pressure washing during maintenance schedules, but the inlet cap must be closed first.

Keep an appropriate distance between the pressure washer and the instrument, and do not direct the water jet at the underside of the instrument because water must not enter the air flow path.

Yes. The AIR XD provides in and out RS485 terminals so multiple MODBUS devices can be daisy-chained.

Some network installations may require a termination resistor across RS485 lines A and B.

SEE MORE RESOURCES

PARTICULATE MONITORING

Image of TX8061 XD1+ Personal Dust Monitor
TX8061 XD1+ Personal Dust Monitor

Image of AIR X Software
AIR X Software

Image of TX8005 AIR XD Dust Monitor
TX8005 AIR XD Dust Monitor

Image of TX8100 AIR XS Silica Monitor
TX8100 AIR XS Silica Monitor

AIR X NEWS + CASE STUDIES

GET AIR X NEWS + UPDATES

    You may unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and how we are committed to protecting and respecting your privacy, please review our Privacy Policy.